TwinCAT library and programming Using this function block the PROFINET controller reads all I&M 0 data (Identification & Maintenance) from a device referenced via the Port input. The frame structure of the I&M0 function corresponds to the index 0xAFF0 [ } 66] according to PROFINET standard. VAR_INPUT VAR_INPUT bStart : BOOL; NETID : T_AmsNetId;(* AMS Net ID from Controller *) PORT : T_AmsPort; (* Port used by Controller to communicate with Device *) END_VAR bStart : The block is activated by a rising edge on this input NETID : AMS Net ID of the controller PORT : Port via which the controller communicates with the device (port = Device ID + 1000hex) VAR_OUTPUT VAR_OUTPUT bBusy :
BOOL; IM_AFF0 : str_IM_0xAFF0; bError : BOOL; iErrorID : UDINT; END_VAR bBusy : When the function block is activated this output is set. It remains set until a feedback is received. While Busy = TRUE, no new command will be accepted at the inputs. IM_AFF0 : Output of the I&M0 frame supplied by the device in a structure. str_IM_0xAFF0. bError : In the event of an error during the command transfer, this output is set once the bBusy output has been reset. iErrorID : Supplies an ADS error number when the output bError is set.
Requirements 6.1.2 FB_PN_IM1_READ Using this function block the PROFINET controller reads all I&M1 data (Information & Maintenance) from a device referenced via the Port input. The frame structure of the I&M1 function corresponds to the index 0xAFF1 [ } 67] according to PROFINET standard. VAR_INPUT VAR_INPUT bStart : BOOL; NETID : T_AmsNetId;(* AMS Net ID from Controller *) PORT : T_AmsPort; (* Port used by Controller to communicate with Device *) END_VAR TS6271 55 Version: 1.2 Development environment Target platform PLC libraries to be linked TwinCAT v2.11.0 R3 PC or CX (x86, ARM) TcProfinetDiag.Lib