TwinCAT library and programming bStart : The block is activated by a rising edge on this input NETID : AMS Net ID of the controller PORT : Port via which the controller communicates with the device (port = Device ID + 1000hex) VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; st_IM_TagFunction : STRING(32); st_IM_TagLocation : STRING(22); bError : BOOL; iErrorID : UDINT; END_VAR bBusy : When the function block is activated this output is set. It remains set until a feedback is received. While Busy = TRUE, no new command will be accepted at the inputs. st_IM_TagFunction : label read out for the function of the device. st_IM_TagLocation : label read out for the installation site of the device. bError :
In the event of an error during the command transfer, this output is set once the bBusy output has been reset. iErrorID : Supplies an ADS error number when the output bError is set. Requirements 6.1.3 FB_PN_IM1_WRITE Using this function block the PROFINET controller writes all I&M1 data (Identification & Maintenance) data to a device referenced via the Port input. The frame structure of the I&M1 function corresponds to the index 0xAFF1 [ } 67] according to PROFINET standard. VAR_INPUT VAR_INPUT bStart : BOOL; NETID : T_AmsNetId;(* AMS Net ID from Controller *) PORT : T_AmsPort; (* Port used by Controller to communicate with Device *) st_IM_TagFunction : STRING(32); st_IM_TagLocation :
STRING(22); END_VAR bStart : The block is activated by a rising edge on this input NETID : AMS Net ID of the controller PORT : Port via which the controller communicates with the device (port = Device ID + 1000hex) st_IM_TagFunction : With this string the functional description is saved to the device. TS6271 56 Version: 1.2 Development environment Target platform PLC libraries to be linked TwinCAT v2.11.0 R3 PC or CX (x86, ARM) TcProfinetDiag.Lib