beckhoff TS6271 — 6.1.7 FB_PN_IM3_WRITE

TwinCAT library and programming 6.1.7 FB_PN_IM3_WRITE Using this function block the PROFINET controller writes all I&M3 data (Identification & Maintenance) data to a device referenced via the Port input. The frame structure of the I&M3 function corresponds to the index 0xAFF3 [ } 67] according to PROFINET standard. VAR_INPUT VAR_INPUT bStart : BOOL; NETID : T_AmsNetId;(* AMS Net ID from Controller *) PORT : T_AmsPort; (* Port used by Controller to communicate with Device *) st_IM_Descriptor : STRING(54); END_VAR bStart : The block is activated by a rising edge on this input NETID : AMS Net ID of the controller PORT :

Port via which the controller communicates with the device (port = Device ID + 1000hex) st_IM_Descriptor : Returns the manufacturer description stored for the device. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; iErrorID : UDINT; END_VAR bBusy : When the function block is activated this output is set. It remains set until a feedback is received. While Busy = TRUE, no new command will be accepted at the inputs. bError : If an error should occur during the transmission of the command, this output is set after the bBusy output has been reset. iErrorID : Supplies an ADS error number when the output bError is set. Requirements TS6271 60 Version:

1.2 Development environment Target platform PLC libraries to be linked TwinCAT v2.11.0 R3 PC or CX (x86, ARM) TcProfinetDiag.Lib