PLC API VAR_INPUT VAR_INPUT sNetID : T_AmsNetId; bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. bExecute : A rising edge starts the read/write cycle, while a falling edge stops it. tTimeout : States the length of the timeout that may not be exceeded by execution of the ADS command. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; sSQLState : ST_DBSQLError; END_VAR bBusy : The command is in the process of being transmitted by ADS. No new command will be accepted as long as "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. nErrID :
Supplies the ADS Error Code [ } 132] or the TcDatabaseSrv_Error_Codes [ } 135] when the bError output is set. sSQLState : Supplies the SQL error code [ } 89] of the specified database type. Requirements 7.1.13 FB_DBRead The FB_DBRead allows values to be read from a database. The function block searches the database table in the "Name" column for the specified sDBVarName and then outputs the corresponding value from the "Value" column. If the sDBVarName searched for is present several times in the database table, the first data record found is output. VAR_INPUT VAR_INPUT sNetID : T_AmsNetId; hDBID : DINT; sDBVarName : STRING(80); cbReadLen : UDINT; pDestAddr : DWORD; TS6420 71 Version:
1.2 Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 PC or CX (x86) TcDatabase.Lib TwinCAT v2.10.0 CX (ARM)