PLC API bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. hDBID : Indicates the ID of the database to be used. sDBVarName : Gives the name of the variable that is to be read. cbReadLen : Indicates the length of the buffer that is to be read. pDestAddr : Contains the address of the buffer which is to receive the data that has been read. bExecute : The command is executed with the rising edge. tTimeout : States the time before the function is cancelled. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; sSQLState : ST_DBSQLError; END_VAR bBusy :
The command is in the process of being transmitted by ADS. No new command will be accepted as long as "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. nErrID : Supplies the ADS Error Code [ } 132] or the TcDatabaseSrv_Error_Codes [ } 135] when the bError output is set. sSQLState : Supplies the SQL error code [ } 89] of the specified database type. Requirements 7.1.14 FB_DBWrite TS6420 72 Version: 1.2 Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 PC or CX (x86) TcDatabase.Lib TwinCAT v2.10.0 CX (ARM)