beckhoff TS6420 — 7.1.20.2 FB_DBRecordInsert

PLC API 7.1.20.2 FB_DBRecordInsert The FB_DBRecordInsert function block allows individual data records to be written into a database. For using this function block, you have to declare the database, you want to write to, in the XML - configuration file. VAR_INPUT VAR_INPUT sNetID : T_AmsNetId; hDBID : UDINT; sInsertCmd : T_MaxString; bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. hDBID : Indicates the ID of the database to be used. sInsertCmd : Indicates which INSERT command is to be executed. bExecute : The command is executed with the rising edge. tTimeout :

States the time before the function is cancelled. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; sSQLState : ST_DBSQLError; END_VAR bBusy : The command is in the process of being transmitted by ADS. No new command will be accepted if "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. nErrID : Supplies the ADS Error Code [ } 132] or the TcDatabaseSrv_Error_Codes [ } 135] when the bError output is set. sSQLState : Supplies the SQL error code [ } 89] of the specified database type. Requirements TS6420 82 Version:

1.2 Development environment Target system type PLC libraries to be linked TwinCAT v2.10.0 PC or CX (x86) TcDatabase.Lib TwinCAT v2.10.0 CX (ARM)