PLC API 7.1.20.3 FB_DBRecordSelect The FB_DBRecordSelect allows individual data records to be read from a database. This function block is not compatible with ASCII files. VAR_INPUT VAR_INPUT sNetID : T_AmsNetID; hDBID : UDINT; sSelectCmd : T_MaxString; nRecordIndex : UDINT; cbRecordSize : UDINT; pDestAddr : DWORD; bExecute : BOOL; tTimeout : TIME; END_VAR sNetID : Is a string containing the AMS network identifier of the target device to which the ADS command is directed. hDBID : Indicates the ID of the database to be used. sSelectCmd : Indicates which SELECT command is to be executed. nRecordIndex : Gives the index of the data record that is to be read. cbRecordSize :
Provides the size of a data record in bytes. pDestAddr : Provides the address of the structure into which the data record is to be written. bExecute : The command is executed with the rising edge. tTimeout : States the time before the function is cancelled. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bError : BOOL; nErrID : UDINT; sSQLState : ST_DBSQLError; nRecords : UDINT; END_VAR bBusy : The command is in the process of being transmitted by ADS. No new command will be accepted if "bBusy" remains TRUE. bError : Becomes TRUE, as soon as an error occurs. nErrID : Supplies the ADS Error Code [ } 132] or the TcDatabaseSrv_Error_Codes [ } 135] when the bError output is set. sSQLState :
Supplies the SQL error code [ } 89] of the specified database type. nRecords : Returns the number of data records. TS6420 83 Version: 1.2