beckhoff — 11.2.10.1 Beckhoff CP9030

Reference | I/O Devices I/O Variables: Inputs: S1 .. S n : Input status of corresponding Special Keys (see also -> "BECKHOFF Knowledge Base"). TermDiag : To this input, a variable (e.g. from TwinCAT PLC) for "Extended Bus Terminal Diagnosis" can be mapped. PlcIFace : The status variable for the register access by PLC-Interface can be mapped here. If it is mapped, the actual status of communication (register access) can be checked. KBusErr : Error status of a K-Bus (if present) connected to the Control Panel CnfErr : Configuration error (e.g. Flash checksum error) PDLenErr : Wrong configured length of process data (e.g.

existing number of LEDs / Special Keys don't match with the System Manager configuration). ExtVoltageOk : External voltage status (when UPS is active) AkkuVoltageOk : Battery voltage status (when UPS is active) AkkuCharging : Battery is charging (when UPS is active) AkkuNotPresent : Battery not detected (when UPS is active) AkkuCharged : Battery fully charged (when UPS is active) AkkuWaiting : Check of Battery charging level. Charging is currently interrupted IdentSwitch : Value of dip switch installed on card ComErr : Communication error between Control Panel and CP9030 card TwinCAT 2 245 Version: 1.7