beckhoff — 11.2.10.2 Beckhoff CP9035

Reference | I/O Devices Outputs: LED 1 -n : Output bits for controlling the LEDs (see Beckhoff Knowledge Base) TermDiag : The status variable for the -> "Extended terminal diagnosis" can be linked here. PlcIFace : The status variable of the PLC interface can be linked or its current value can be checked here. EnableUPS : Output bit for manual activation of UPS (only to be used if the UPS has not been activated via the UPS configuration) DisplayOff : Switches off the background illumination on the control panel KbdOff :

Switches off the keyboard of a connected control panel (important when several control panels are connected via several CP9030 cards) Data exchange To enable the exchange of data between the control panel and CP9030, at least one variable must be linked. The linked task must be running or the async mode mentioned above must be set! Otherwise the handshake between PC and CP9030 is not performed, i.e. no data is exchanged with the control panel. 11.2.10.2 Beckhoff CP9035 | Beckhoff CP9035 The CP9035 card acts as a PC-side connector for the Beckhoff C ontrol P anel - Link system. The difference to the CP9030 [ } 244] card is, that the CP9035 uses a PCI slot instead of an ISA one.

With CP-Link, the Beckhoff Control Panel can be connected via coax cables to the PC, which makes long distances available. Beside TFT display, Mauspad/Touchscreen and Keyboard information, a Beckhoff Control Panel can contain Special Keys and LEDs, which can be accessed through TwinCAT ( see also: Beckhoff IPC - Special Keys and UPS). "CP9030/CP9035" Tab PCI Bus/Slot : The appropriate PCI slot, where the CP9035 sits in, can/has to be selected here (see also Search ). Search : With the use of this button, the System Manager scans the current PC for CP9035 cards. Alternatively, the PC can be searched for by TwinCAT supported I/O Devices [ } 133] with the -> " Scan Devices [ } 97] " function.

Buttons : The number of implemented Special Keys at the Control Panel has to be selected here. Default number is 27, which suits for the most of the Control Panels (see also -> "BECKHOFF Knowledge Base"). LEDs : The number of implemented LEDs and/or lamps at the Control Panel has to be selected here. Default number is 27, which suits for the most of the Control Panels (see also -> "BECKHOFF Knowledge Base"). Async Mode : With activated Checkbox, the communication with the I/O driver even continuous, if the linked task (e.g. a PLC task) is not active (anymore). TwinCAT 2 246 Version: 1.7