Reference | Boxes PDO mapping [ } 382] The AX2000 has 4 transmit PDOs (TxPDO1..4) and 4 receive PDOs (RxPDO1..4). The content of these messages (PDOs) depends on the operation mode and the mapping. There are 7 predefined RxPDOs and 6 predefined TxPDOs. In addition to this, there is an option to compose the message. Do not map every object Not every object can be mapped in a freely definable PDO. For the "Position control", both the RxPDO and the TxPDO were configured freely. For "Velocity control", the TxPDO was taken from the pool of predefined PDOs. The RxPDO was defined freely. Example:
"ADS" Tab Via the shown AmsNetID + Port number (address) it is possible to read and write parameters from/to the AX2000 (e.g. from PLC). TwinCAT 2 333 Version: 1.7 Object in- dex Sub Idx Length Value Description 0x6040 2 2 0 Sets the drive ControlWord to null. The controller is now in the "Switch on disable" state. The AX2000 is ready to be switched on, parameters can be transferred, DC link voltage can be switched on, motion functions cannot yet be executed 0x3683 1 1 3 ASCII command: SYNCSRC 0x363b 1 1 3 Synchronization mode specially adapted to the CAN interface, ASCII command: FPGA 0x35d5 1 1 40 Value = Task Cycl / Velocity controller Cycl 40 = 1000 µs / 250 µs, ASCII command:
PTBASE 0x6060 0 2 0xFA This sets the OPMODE of the drive: 0xFA = Position control 0xFE = Velocity control 0x3672 1 1 2 Influencing the CANopen state machine by Enable/Disable. Object in- dex Sub Idx Lengt h Value Description 0x2600 0 1 0x25 Selection of a freely definable RxPDO (37..40) 0x1600 0 0 0 Delete mapping 0x1600 1 4 0x60400010 The first element of the message is the ControlWord (0x6040) Subelement SI (0x00) Length (0x10) 16-bit 0x1600 2 4 0x20220420 The first element of the message is the TargetPosition (0x2022) Subelement SI (0x04) Length (0x20) 32-bit