Reference | Boxes The first list view displays the configuration of the FMMUs The second list view displays the configuration of the Sync Manager: TwinCAT 2 368 Version: 1.7 Column Description L Start Specifies from which logical address the FMMU starts to map the data. The start bit is set according to the number that follows the point (0Xnnnnnnnnn.StartBit.) Length Specifies how many bytes are mapped by the logical addressing. L EndBit End bit of the logical address. If the logical address should be configured to a byte, the start bit must be configured to 0(L Start = 0xnnnnnnnn.0) and this entry must be set to 7. P Start Specifies the physical address the logical address points to.
Column Description Start Specifies from which address the Sync channel is active. Length Length of the Sync channel in bytes. If the length is 0 the Sync channel is not activated. Data Configuration data written to the sync manager.