beckhoff — 12.5.3 AX2xxx Drive - Status and Error Codes

Appendix | Appendix E: AX2xxx parameters TwinCAT 2 458 Version: 1.7 Variable Data Type Value AX2xxx Display Designation DriveError (can also be linked byte-wise with help of the variables DriveError0,DriveErr or1,DriveError2 andDriveError3) The equivalent ASCII command is: ERRCODE * resp. ERRCODE UINT32 0x00000001 F01 Error heat sink temperature is set if the current heat sink temperature (TEMPH) goes beyond the max. allowed value (MAXTEMPH) 0x00000002 F02 Error overvoltage is set, if the voltage inside the DC-link circuit goes beyond the max. allowed value (VBUSMAX).

0x00000004 F03 Error position controller (drive) if drive internal position controller is used (OPMODE=6/ SERCOS) and the lag distance is too high. Means, if in the above case the max. revolutions per minute value goes beyond (VLIM / VLIMN). 0x00000008 F04 Feedback error (Resolver) is set, if the amplitude of the resolver / encoder signals goes below the min. value. 0x00000010 F05 Error undervoltage is set, if the voltage inside the DC-link circuit goes below the min. allowed value (VBUSMIN 0x00000020 F06 Error motor temperature is set if the resistance of the motor thermoelement (TEMPM) goes beyond the max. allowed value (MAXTEMPM). 0x00000040 F07 Internal supply voltage (aux.

voltage) not ok.. 0x00000080 F08 Speed error is set if the current motor revolution per