Appendix | Appendix E: AX2xxx parameters TwinCAT 2 459 Version: 1.7 Variable Data Type Value AX2xxx Display Designation minute value (V) goes beyond the max. allowed value (VOSPD). 0x00000100 F09 Error EEPROM is set, if the read/ write process with the serial EEPROM fails. It can happen because of a bad EEPROM or wrong checksum. In the second case, an additional try to save to EEPROM, may help. 0x00000200 F10 Reserved 0x00000400 F11 Brake error is set, if the brake input notices an error (e.g. brake not connected). 0x00000800 F12 Reserved 0x00001000 F13 Error ambient temperature is set, if the ambient temperature (TEMPE) goes beyond the max.
allowed value (MAXTEMPE) 0x00002000 F14 Amplifier error Following problems could cause the error: Line output grounded to earth, motor short circuit or ballast circuit shorted. 0x00004000 F15 Error I2T exceeded max is set, if I2T is at 115% (at FOLDMODE=0) respectively 105% (at FOLDMODE=1). 0x00008000 F16 Supply voltage not correct is set, if 2 or 3 phases of supply voltage are missing. For additional information see manuals supplied with AX2xxx drive, also. 0x00010000 F17 Error A/D Converter