beckhoff — 12.5.3 AX2xxx Drive - Status and Error Codes

Appendix | Appendix E: AX2xxx parameters TwinCAT 2 461 Version: 1.7 Variable Data Type Value AX2xxx Display Designation 0x01000000 F25 Error in commutation At this error message, the motor has a commutation problem (uncontrolled motor behavior). The commutation treshold value can be changed under VCOMM, the unit is RPM (rounds per minute). 0x02000000 F26 Error in calibration (hardware limit switch) is defined by REFLS. 0x04000000 F27 Error AS-Option is set, if amplifier was enabled during activation of the optional starting inhibiting circuit (part no.: AX20xx- yyyy-0001). 0x08000000 F28 Error "external position setpoint offset" External position setpoint offset beyond limit.

0x10000000 F29 SERCOS error 0x20000000 F30 SERCOS emergency stop timeout 0x40000000 F31 Reserved 0x80000000 F32 System error shows an internal error. This error is generated at drive startup if system check didn't succeed during initialization. For further information, see detailed AX2000 / AX2500 manuals supplied with drive. DriveState (can also be linked byte-wise with help of the variables UINT32 0x00000001 n01 Warning I2T- threshold value exceeded is set, if I2T goes beyond the limit set under I2TLIM.