beckhoff — 12.5.3 AX2xxx Drive - Status and Error Codes

Appendix | Appendix E: AX2xxx parameters TwinCAT 2 463 Version: 1.7 Variable Data Type Value AX2xxx Display Designation start command with valid position values is supplied). 0x00000040 n07 Warning: Software limit switch 2 beyond maximum is set, if the value of the software limit switch 2 is beyond SWE2. In addition, the warning is set, if a motion task was started with a target position beyond the value specified in drive object SWE2. The warning message is cleared as soon as SWE2 stays below and a negative speed setpoint value is passed over (means, when a start command with valid position values is supplied). 0x00000080 n08 Warning:

Wrong start command is set if it was tried to start an undefined (missing checksum) motion task. The warning is cleared automatically if a valid start command is supplied. 0x00000100 n09 Warning: Reference point (calibration) not set is set if a motion task was initiated without a calibration/ homing done before. 0x00000200 n10 Warning: PSTOP activated is set if hardware limit switch PSTOP (stop switch in positive direction) is activated. Warning is cleared as soon as the limit switch is released again. 0x00000400 n11 Warning: NSTOP activated