Appendix | Appendix E: AX2xxx parameters TwinCAT 2 464 Version: 1.7 Variable Data Type Value AX2xxx Display Designation is set if hardware limit switch NSTOP (stop switch in negative direction) is activated. Warning is cleared as soon as the limit switch is released again. 0x00000800 n12 Warning: Default motor data loaded is set during drive startup, if the motor ID of the serial EEPROM and the motor ID of the SIN/ COS encoder don't match. 0x00001000 n13 Slot warning (I/O card) is set, if there is a dysfunctionality with the optional I/O card (part no.: AX2090- I001), which is for starting of predefined (inside drive) motion tasks.
0x00002000 n14 Recognition of MPHASE (FBTYPE=7) 0x00004000 n15 Warning: Wrong VCT-Entry selected (table error) is set, when a wrong VCT entry is selected and to be activated. 0x00008000 n16 Warning active n17 .. n31 is set, if one or several warnings in the range between n17.. n31 are active 0x00010000 Motion task active Is set, if a motion task is started (motion task, jog or homing move). Is cleared, if the action is finished or a STOP - command is executed 0x00020000 Reference point is set. Is set, if the homing move was done or a absolute encoder feedback device is