beckhoff — 12.5.3 AX2xxx Drive - Status and Error Codes

Appendix | Appendix E: AX2xxx parameters TwinCAT 2 466 Version: 1.7 Variable Data Type Value AX2xxx Display Designation (SWCNFG , SWE3 , SWE3N ) is true, otherwise low 0x02000000 Position register 4 Is high, if the configured condition (SWCNFG , SWE4 , SWE4N ) is true, otherwise low 0x04000000 Initialization phase finished Is set, if the initialization phase of the drive is finished (takes about 15s). 0x08000000 Position register 5 Is high, if the configured condition (SWCNFG2 , SWE5 , SWE5N ) is true, otherwise low 0x10000000 Motor stand still message Is high, if the actual motor velocity is lower than the threshold VEL0 , otherwise low.

0x20000000 Safety relays selected Is high, if the safety relay of the AS- option (part no: AX20xx-yyyy-0001) is switched on, otherwise low. 0x40000000 Output stage enabled Is high, if the soft- and the hardware enable is present, otherwise low. 0x80000000 Drive is in error condition Is set, if the drive has a fault (output stage is disabled, error number is displayed). The command ERRCODE gives the error in plain text. The bit is cleared if the drive is reset or the command CLRFAULT is send.