Appendix | Automation Interface 12.5.4 ASCII Object Description | ASCII Object Description The Beckhoff AX2000 and AX2500 drive contains numerous ASCII objects to read or manipulate internal parameters. These ASII objects can be accessed fieldbus-independently via ASCII commands in read- and some of them even in write mode. Some networks are using the ASCII commands during initialization of the axes through TwinCAT (e.g. Beckhoff Lightbus or Real-Time Ethernet). However, not all parameters are relevant in combination with TwinCAT NC-PTP or TwinCAT NC-I. In any case, the support of the individual command depends on the Firmware revision of the drive ( => VER ) !
A listing of the supported commands can be found under: AX2xxx Reference - ASCII Object Description . At drives used under SERCOS, similar parameters are defined according to the IEC 61491 standard. For a description of the Sercos ID ent N umbers supported by AX2000 respectively AX2500, please refer to: AX2xxx-B750 Reference . If a dedicated IDN matches the function of one of the ASCII objects, it is named in the table of the correlating IDN ( for example : S-0-0030 == VER).
12.6 Automation Interface | Automation Interface TwinCAT Automation Interface enables an efficient engineering process by giving customers the possibility to automate the configuration of a full TwinCAT project configuration. The documentation of the TwinCAT Automation Interface is located in TwinCAT > System > Automation Interface TwinCAT 2 467 Version: 1.7 Variable Data Type Value AX2xxx Display Designation State UINT8 0x01 Command error from AX2xxx-Bx00 interface. 0x02 Error in input data from AX2xxx-Bx00 interface. 0x04 Error in output data from AX2xxx-Bx00 interface. 0x08 Timeout from AX2xxx-Bx00 interface. 0x10 Error K-Bus Reset from AX2xxx-Bx00 interface.