beckhoff — 5.4.4 Axes - Dialog: Functions

NC Configuration | Settings dialogs Maximum velocity (V max) The maximum velocity of the axis set at Global [ } 75] is displayed here. Acceleration time Axis acceleration time until V max is reached. Deceleration time Time needed from V max to velocity 0 mm/s. Acceleration characteristic Slider for indirect setting of acceleration and deceleration time. Acceleration Specifies the acceleration in mm/sІ . Deceleration Specifies the deceleration in mm/sІ . Jerk Specifies the jerk required for the targeted acceleration. 5.4.4 Axes - Dialog: Functions | Axes - Dialog:

Functions Especially in the time of the initial commissioning of axes, one is dependent on aids from the software or hardware side. The advantage of e.g. a software controlled, direct raw value output to the drive, instead of using a battery box, is obvious. TwinCAT 2 78 Version: 1.7