NC Configuration | Settings dialogs Set position In addition to the actual position (large display field), the current target position of the drive is also displayed. Extended axis start Start type: here, a distinction is made between relative, absolute, modulo, etc... start of the axis. Target position: desired target position of the axis. Velocity: desired positioning velocity after axis start-up. Acceleration: if no automatically calculated acceleration is desired, the checkbox can be used to activate the acceptance of the value entered on the right. Deceleration : the checkbox activates the acceptance of the deceleration value entered on the right, if its manual entry is desired. Jerk:
the checkbox activates the acceptance of the value entered on the right for the jerk (in the example no value is entered yet). Start : starts the axis positioning with the entered or calculated values. Stop : stops the execution of the axis positioning. Drive output Output type: only a percentage output (e.g. corresponding to 100% = 10V) to the drive can be selected here. Output value: percentage setpoint of the maximum possible output value of the terminal or the Mxxxx module. Start: starts the output of the set value to the drive. Safety mechanisms, such as software end position monitoring etc.. are not considered. Stop: stops the output of the set value to the drive. TwinCAT 2 79 Version:
1.7