beckhoff — 5.5.1 NC manual mode

NC Configuration | NC operation - Has order, Moves larger, Moves smaller, Coupled, In target position (i.e. in the set target window for a preset time), In position range (i.e. in the preset position range). - Enables for controller, feed+, feed-. Input fields Partly with download by mouse click on the rectangular button. After pressing this arrow symbol, the value of the input field is transferred to the NC server. Function keys "Set" window This window allows - without PLC - to set certain enables and values. If a PLC is active, the set values are generally overwritten periodically and do not take effect. TwinCAT 2 87 Version:

1.7 Enable Data type Value Unit Description Kv-factor FLOAT >=0 [mm/s]/mm P controller Kv- factor. Reference velocity FLOAT >0 mm/s Reference velocity at maximum output size (e.g. at 10 V). Target position FLOAT mm Target position where the download calls the "New target position" function. Travel velocity FLOAT >0 mm/s Global set velocity. If the distance is too short to reach this velocity, a smaller suitable target velocity is automatically calculated and activated.

Key Function F1 Reverse at velocity Hand Max F2 Reverse at velocity Hand Min F3 Move forward at velocity Hand Min F4 Move forward at velocity Hand Max F5 Start with the values set in the input fields and the values set in the "Dynamics" menu F6 Stop F8 Reset F9 Calibrate with the values set in the "Global" menu. Notice The signal of a referencing cam must be mapped into the axis data structure (Axis.PlcToNc.ControlDword.5) by the PLC so that the sequence initiated with F9 can react to the cam.