beckhoff — 5.5.2 Online display axis channel

NC Configuration | NC operation 5.5.2 Online display axis channel | Online display axis channel When the TwinCAT system is started and the current configuration is loaded, the setpoint and actual values of the axis channel selected in the tree view can be displayed in list view under "Online". TwinCAT 2 88 Version: 1.7 Enable Data type Value Unit Description Controller BOOL Without controller enable, the controller is not active and 0 V are output. Feed+ BOOL The axis cannot be started in the positive direction without an enable Feed+.

If the axis moves in positive direction and the enable Feed+ is removed, then the axis is stopped (the axis does not start again if later the enable is set again). Feed- BOOL The axis cannot be started in the negative direction without an enable Feed-. If the axis moves in negative direction and the enable Feed- is removed, then the axis is stopped (the axis does not start again if later the enable is set again). Override FLOAT >0 % Velocity override in % in the range [0.0,100.0] related to the target velocity.