Overview of NC errors TwinCAT 25 Version: 1.1 Error(Hex) Error(Dec) Error type Description 42C9 17097 Parameter "Set velocity less than or equal to 0.0 is invalid" A value less than or equal to 0.0 for the set velocity (CNC) is not allowed, since the set velocity is positive by definition, and a set velocity of 0.0 cannot generate any motion. 42CA 17098 Address "Address for look-ahead invalid" (INTERNAL ERROR) The address supplied for the look-ahead is invalid. 42CB 17099 Function "Set value generator SAF active" Starting the set value generator (SAF) has been refused, since the SAF task is already active.
42CC 17100 Function "CNC set value generation not active" Stop or change of override refused, because the set value generation is not active. 42CD 17101 Function "CNC set value generation in the stop phase" Stop or change of override refused, because the set value generation is in the stop phase. 42CE 17102 Parameter "Override not allowed" An override of less than 0.0% or more than 100.0% is invalid. 42CF 17103 Address "Invalid table address" (INTERNAL ERROR) The table address given for the initialization of the set value generator is invalid, or no valid logger connection (report file) is present. 42D0 17104 Parameter "Invalid table entry type" The given table entry type is unknown.
42D1 17105 Memory "Memory allocation failed" Memory allocation for the table has failed. 42D2 17106 Memory "Memory allocation failed" Memory allocation for the filter has failed. 42D3 17107 Parameter "Invalid parameter" Filter parameter is not allowed. 42D4 17108 Function "Delete Distance To Go failed" Delete Distance to go (only interpolation) failed. This error occurred, if e.g. the command 'DelDTG' was not programmed in the actual movement of the nc program.
42D5 17109 Internal "The setpoint generator of the flying saw generates incompatible values (internal error)" 42D6 17110 Function "Axis will be stopped since otherwise it will overrun its target position (old PTP setpoint generator)" If, for example, in case of a slave to master transformation for the new master a target position is commanded that will be overrun because of the actual dynamics the axis will be stopped internally to guarantee that the target position will not be overrun.
42D7 17111 Function "Internal error in the transformation from slave to master." 42D8 17112 Function "Wrong direction in the transformation of slave to master." 42DA 17114 Parameter "Parameter of Motion Function (MF) table incorrect" The parameter of the Motion Function (MF) are invalid. This may refer to the first time created data set or to online changed data. 42DB 17115 Parameter "Parameter of Motion Function (MF) table incorrect" The parameter of the Motion Function (MF) are invalid. This may refer to the first time created data set or to online changed data. The error cause can be, that an active MF point (no IGNORE point) points at a passive MF point (IGNORE point).