Overview of NC errors TwinCAT 24 Version: 1.1 Error(Hex) Error(Dec) Error type Description 42B3 17075 Parameter "Helix is a circle" The helix has degenerated to a circle, and should be entered as such. 42B4 17076 Parameter "Helix is a straight line" The helix has degenerated to a straight line, and should be entered as such. 42B5 17077 Parameter "Guider parameter not allowed" One of the guider's parameters leads to logical errors and/or to an FPU exception. 42B6 17078 Address "Invalid segment address" (INTERNAL ERROR) The geometry segment does not have a valid geometry structure address or does not have a valid dynamic structure address.
42B7 17079 Parameter "Unparametrized generator" (INTERNAL ERROR) The SVB generator is not yet parameterized and is therefore unable to operate. 42B8 17080 Address "Unparametrized table" (INTERNAL ERROR) The table has no information concerning the address of the corresponding dynamic generator.
42BA 17082 Internal "The calculation of the arc length of the smoothed path failed (internal error)." 42BB 17083 Parameter "The radius of the tolerance ball is too small (smaller than 0.1 mm)." 42BC 17084 Internal Error while calculating DXD-Software-Limit switches (internal error) 42BD 17085 Function "NC-Block violates software limit switches of the group" At least one path axis with active software limit monitoring has violated the limit switches. Therefore the geometric entry is denied with an error.
42BE 17086 Parameter "GROUPERR DXD SOFTENDCHECK" _ _ 42BF 17087 Parameter "GROUPERR DXD RTTG VELOREFERENCE" _ _ _ 42C0 17088 Internal "Interpolating group contains axes of an incorrect axis type" An interpolating 3D group may only contain continuously guided axes of axis type 1 (SERVO). 42C1 17089 Internal "Scalar product cannot be calculated" The length of one of the given vectors is 0.0. 42C2 17090 Internal "Inverse cosine cannot be calculated" The length of one of the given vectors is 0.0. 42C3 17091 Parameter "Invalid table entry type" The given table entry type is unknown.
42C4 17092 Parameter "Invalid DIN66025 information type" (INTERNAL ERROR) The given DIN66025 information type is unknown. Known types: G0, G1, G2, G3, G17, G18, G19. 42C5 17093 Parameter "Invalid dimension" (INTERNAL ERROR) The CNC dimension is unknown. Known dimensions: 1, 2, 3. Or: The CNC dimension is invalid for the given geometrical object. For a circle the dimension must be 2 or 3, while for a helix it must be 3. 42C6 17094 Parameter "Geometrical object is not a straight line" The given object, interpreted as a straight line, has a length of 0.0.
42C7 17095 Parameter "Geometrical object is not a circle" Interpreted as a circular arc, the given object has a length of 0.0, or an angle of 0.0 or a radius of 0.0. 42C8 17096 Parameter "Geometrical object is not a helix" Interpreted as a circular arc, the given object has a length of 0.0, or an angle of 0.0, or a radius of 0.0. or a height of 0.0.