TwinCAT PLC Library Hydraulics - Version 1.4 — 4.3.23 ST_TcHydAxRtData (from V3.0)

PLCopen Motion Control stPosCtrlr: stbkplcinternal_cplxctrl; stVeloCtrlr: stbkplcinternal_cplxctrl; (*------------------------------------------------------*) sTopBlockName: STRING(83) := ''; (*------------------------------------------------------*) END_STRUCT END_TYPE bActPosCams : The current position cam of the axis. This value is only used, if iTcMc_EncoderDigCam is set as encoder type. bActPosOffsetEnable : A TRUE in this variable activates actual value influencing. See also under fActPosOffset . bBrakeOff : The control signal for an external brake. An output variable of the profile generators. bBrakeOffInverted : The inverted bBrakeOff signal. bChangeCount :

This value is incremented with each parameter change. bEncAlignRefShift : Reserved. bEncDoLatch : This signal is used for communication by the MC_Home_BkPlcMc [ } 57] and MC_AxRtEncoder_BkPlcMc [ } 135] function blocks of the axis during homing. bEncLatchValid : This signal is used for communication by the MC_Home_BkPlcMc [ } 57] and MC_AxRtEncoder_BkPlcMc [ } 135] function blocks of the axis during homing. bLocked_Estop : A TRUE in this variable prevents the control value generators from exiting the state iTcHydStateEmergencyBreak / McState_Errorstop, despite the fact that the drive outputs are reduced to 0. Used by MC_EmergencyStop_BkPlcMc [ } 50] and MC_ImediateStop_BkPlcMc [ } 59] .

bParamFileComplete: This flag is set if a corresponding identifier was found at the end of the file when the parameters were loaded and the CRC check was successful. bParamsUnsave : The function blocks MC_WriteParameter_BkPlcMc [ } 43] and MC_WriteBoolParameter_BkPlcMc [ } 41] set this flag if they change a parameter value. An MC_AxParamSave_BkPlcMc [ } 204] function block clears the flag when the parameters are successfully saved. In online mode of the PlcMcManager [ } 252] , this flag is used for the status display. bStartAutoIdent: bUnalignedOverlap: The characteristic of the overlap compensation is defined here. fActForce : [N, kN] Actual force of the cylinder.

This value is usually determined by an acquisition function block for acquisition of actual force or pressure values [ } 20] . fActiveOverlap : [1] The current output of the overlap compensation. An output variable of the profile generators. fActPos : [mm] The current actual position of the axis. This value is usually determined by an encoder function block. fActPosOffset : [mm] The offset used to influence the actual value. If bActPosOffsetEnable is TRUE, this offset is added to fActPos . If fActPosOffset changes, fActVelo is unaffected. If bActPosOffsetEnable is TRUE, fActPosOffset takes effect immediately and without ramp. NOTE!

If actual value influencing is active during homing, bActPosOffset is taken into account when the actual position is set. Example: If the reference position is 100.0 mm and the offset is 1.0 mm, the actual position at the point of the zero pulse is set to 101.0 mm. If influencing is subsequently deactivated or set to 0.0, the actual position at the point of the zero pulse shows the value 100.0, just like it would have done during homing without influencing. PLC Library Hydraulics 101 Version: 1.4