TwinCAT PLC Library Hydraulics - Version 1.4 — 4.3.23 ST_TcHydAxRtData (from V3.0)

PLCopen Motion Control NOTE! This function is only implemented for the following encoder types: iTcMc_EncoderCoE_DS406, iTcMc_EncoderEL3255, iTcMc_EncoderSim, iTcMc_EncoderEL5101, iTcMc_EncoderKL5101, iTcMc_EncoderKL5111, iTcMc_EncoderEL5001, iTcMc_EncoderKL5001, iTcMc_EncoderKL3002, iTcMc_EncoderEL3102, iTcMc_EncoderKL3042, iTcMc_EncoderKL3062, iTcMc_EncoderEL3142, iTcMc_EncoderEM8908_A, iTcMc_EncoderEL3162, iTcMc_EncoderKL3162. NOTE! If one of the types listed is set for an for an I/O device that is compatible with one of these types, the function described is also realized. fActPosDelta: [mm] The change of the actual position relative to the previous cycle. fActPressure :

[bar] Actual pressure in the cylinder. This value is usually determined by an acquisition function block for acquisition of actual force or pressure values [ } 20] . fActPressureA : [bar] Actual pressure on the A-side of the cylinder. This value is usually determined by an acquisition function block for acquisition of actual force or pressure values [ } 20] . fActPressureB : [bar] Actual pressure on the B-side of the cylinder. This value is usually determined by an acquisition function block for acquisition of actual force or pressure values [ } 20] . fActVelo : [mm/s] The current actual velocity of the axis. This value is usually determined by an encoder function block. fBlockDetectDelay :

[s] The delay time for the detection of the function block during homing on block. This value is initialized with 2.0 seconds to reflect the default behavior of previous versions. If a different time is required, it must be updated before homing commences. If a value of less than the cycle time is detected when homing commences, the default value of 2.0 seconds is entered automatically. This value is not saved as a parameter. This variable has been available under TC2 in V3.0.41 from 12 October 2017. fClampingOutput : [V] An output variable of the profile generators. fDestAcc : [mm/s 2 ] The acceleration specified by the current or last executed motion command. fDestCreepDistance :

[mm] Up to V3.0.7: The creep distance. fDestCreepSpeed : [mm/s] Up to V3.0.7: The creep speed. fDestCreepDistanceP : [mm] From V3.0.8: The creep distance in positive direction. fDestCreepSpeedP : [mm/s] From V3.0.8: The creep speed in positive direction. fDestCreepDistanceM : [mm] From V3.0.8: The creep distance in negative direction. fDestCreepSpeedM : From V3.0.8: The creep speed in negative direction. fDestDec : [mm/s 2 ] The deceleration specified by the current or last executed motion command. fDestJerk : [mm/s 3 ] The jerk specified by the current or last executed motion command. fDestPos : [mm] The currently active target position. fDestSpeed :

[mm/s] The velocity specified by the current or last executed motion command. fDistanceToTarget : [mm] The current remaining distance of the axis. This value is usually determined by a generator function block. fEnc_RefShift : [mm] The offset between the converted (perhaps internal extended) counter value of an incremental encoder input terminal and the actual position of the axis. This offset is determined through homing, e.g. with an MC_Home_BkPlcMc [ } 57] function block, or manipulated with an MC_SetPosition_BkPlcMc [ } 39] function block. fLatchedPos :

[mm] The position (taking into account current offsets) at which homing took place or where the components of the actual value acquisition (encoder, I/O electronics) were switched on. fLagCtrlOutput : [1] The normalized output of the position controller. An output variable of the profile generators. PLC Library Hydraulics 102 Version: 1.4