PLCopen Motion Control Behavior of the function block: Enable logic As long as Enable for the function block or the axis controller is FALSE, the function block does not become Active . The comparison value for monitoring the compensation is initialized and the time measurement for the Done message is reset. If the enable conditions are met and the axis is not in idle state (i.e. it is in motion), the time measurement for the Done message is also reset. If the enable conditions are met and the axis is in idle state, the function block 'Compensation&Timing' is processed. Irrespective of these preconditions, the function block' Feedback' is processed. Enable logic:
Behavior of the function block: Compensation&Timing A correction value is formed from the lag error and the response of the controller. The bandwidth of the possible axis controller parameterization is taken into account. A delta value (maximum change in zero compensation per cycle) is formed from this correction value and Tn . Tn defines a ramp time for an PLC Library Hydraulics 111 Version: 1.4