PLCopen Motion Control x: Represents a placeholder for different characters. iTcMc_DriveIx2512_1Coil The function block deals with processing of the axis control value for output on an IP2512 PWM fieldbus module. iTcMc_DriveIx2512_2Coil The function block deals with processing of the axis control value for output on an IP2512 PWM fieldbus module. iTcMc_DriveEL2535 The function block prepares the control value of the axis for output on a current-controlled PWM output terminal. This terminal provides two independent output stages and can be used for the following valve types: Proportional valve with spring center position and two coils without permanent magnets:
nDrive_Type = iTcMc_DriveEL2535_2Coil Both channels are required for one valve. The terminal cannot be used for another valve at the same time. With this type of valve, a proportion of the full current in the directionally active coil with currentless countercoil is required to move the slider to the desired position. For -100% .. 0% .. +100% control, the terminal block generates the output values 0 .. 0 .. 32767 in uiDacOutA and 32767 .. 0 .. 0 in uiDacOutB. Proportional valve with spring end position and coil without permanent magnets: nDrive_Type = iTcMc_DriveEL2535_1Coil PLC Library Hydraulics 128 Version:
1.4 Manufacturer Type Description Moog D638Exxx Proportional valve Parker DxxFP /DxxFE /TDP /TPQ Proportional valve I/O variable Interface.Variable Use Data out ST TcPlcDeviceOutput.uiDacOutA _ Output of the PWM factor. I/O variable Interface.Variable Use Data out ST TcPlcDeviceOutput.uiDacOutA _ Output of the PWM factor for coil 1. Data out ST TcPlcDeviceOutput.uiDacOutB _ Output of the PWM factor for coil 2. I/O variable Interface.Variable Use Channel1.PWM Output ST TcPlcDeviceOutput.uiDacOutA _ Output of the PWM factor for coil 1. Channel2.PWM Output ST TcPlcDeviceOutput.uiDacOutB _ Output of the PWM factor for coil 2. ST TcPlcDeviceOutput.nDacOut _ DO NOT USE!
Channel1.Status ST TcPlcDeviceInput.uiStatus _ Status of the first device channel Channel2.Status ST TcPlcDeviceInput.uiTerminalSt _ ate2 Status of the second device channel Channel1.Control ST TcPlcDeviceOutput.uiDriveCtrl _ Control of the first device channel Channel2.Control ST TcPlcDeviceOutput.uiTerminal _ Ctrl2 Control of the second device channel InfoData.State ST TcPlcDeviceInput.uiDriveBoxSt _ ate Connection monitoring, condition monitoring. WcState ST TcPlcDeviceInput.wDriveWcSt _ ate Connection monitoring. InfoData.AdsAddr ST TcPlcDeviceInput.sDrvAdsAdd _ r Automatic identification, parameterization.