TwinCAT PLC Library Hydraulics - Version 1.4 — 4.4.2.1 MC_AxRtDrive_BkPlcMc (in V3.0)

PLCopen Motion Control Only one channel is required here. The terminal can also be used for another valve. The I/O variables of the second channel must be used for this purpose. With this type of valve, 50% of the full power supply is required to move the slider to the center position. The terminal module generates the output values 0 .. 16384 .. 32767 for -100% .. 0% .. +100% control. Proportional valve with spring center position and a coil with permanent magnets: nDrive_Type = iTcMc_DriveEL2535_1Coil Only one channel is required here. The terminal can also be used for another valve. The I/O variables of the second channel must be used for this purpose.

This type of valve requires a bipolar current supply, which corresponds to the operating principle of a ±10 V terminal. The output value generated by the terminal block is to be adjusted as follows AFTER the drive function block has been called by the application: ST_TcPlcDeviceOutput.nDacOut := 2 * (ST_TcPlcDeviceOutput.nDacOut - 16384); iTcMc_DriveEL4132 The function block deals with processing of the axis control value for output on a ±10 V output terminal. PLC Library Hydraulics 129 Version: 1.4 I/O variable Interface.Variable Use ST TcPlcDeviceOutput.uiDacOutA _ DO NOT USE! ST TcPlcDeviceOutput.uiDacOutB _ DO NOT USE!

Channel1.PWM Output ST TcPlcDeviceOutput.nDacOut _ Output of the PWM factor. Channel1.Status ST TcPlcDeviceInput.uiStatus _ Device status Channel1.Control ST TcPlcDeviceOutput.uiDriveCtrl _ Device control. InfoData.State ST TcPlcDeviceInput.uiDriveBoxSt _ ate Connection monitoring, condition monitoring. WcState ST TcPlcDeviceInput.wDriveWcSt _ ate Connection monitoring. InfoData.AdsAddr ST TcPlcDeviceInput.sDrvAdsAdd _ r Automatic identification, parameterization. I/O variable Interface.Variable Use ST TcPlcDeviceOutput.uiDacOutA _ DO NOT USE! ST TcPlcDeviceOutput.uiDacOutB _ DO NOT USE! Channel1.PWM Output ST TcPlcDeviceOutput.nDacOut _ Output of the PWM factor.

Channel1.Status ST TcPlcDeviceInput.uiStatus _ Device status Channel1.Control ST TcPlcDeviceOutput.uiDriveCtrl _ Device control. InfoData.State ST TcPlcDeviceInput.uiDriveBoxSt _ ate Connection monitoring, condition monitoring. WcState ST TcPlcDeviceInput.wDriveWcSt _ ate Connection monitoring. InfoData.AdsAddr ST TcPlcDeviceInput.sDrvAdsAdd _ r Automatic identification, parameterization. I/O variable Interface.Variable Use Output ST TcPlcDeviceOutput.nDacOut _ Operation: Output of the velocity signal. InfoData.State ST TcPlcDeviceInput.uiDriveBoxSt _ ate Connection monitoring, condition monitoring. WcState ST TcPlcDeviceInput.wDriveWcSt _ ate Connection monitoring.