Knowledge Base Device-specific error codes of function block MC_Power_BkPlcMc These values appear at the ErrorID output of an MC_Power_BkPlcMc function block, if an error is reported by the external device. PLC Library Hydraulics 241 Version: 1.4 Constant Hexadeci- mal Decimal Description dwTcHydErrCdHomingType 16#4F00 20224 Referencing method (nEnc HomingType in _ ST TcHydAxParam) is not permitted. _ dwTcHydErrCdEncCutOff 16#4F01 20225 The limit frequency for the actual value acquisition has been exceeded. dwTcHydErrCdIllegalDistan ce 16#4F02 20226 Distance is invalid: zero or negative. dwTcHydErrEncDisconecte d 16#4FF0 20464 Encoder hardware is uncoupled. Possible causes:
• the fieldbus connection is interrupted • the power supply for the device is not available • the device is faulty • another device, which is located in the fieldbus connection between the controller and the device, has no power supply or is faulty dwTcHydErrDriveDisconect ed 16#4FF1 20465 Drive hardware is uncoupled. Possible causes: • the fieldbus connection is interrupted • the power supply for the device is not available • the device is faulty • another device, which is located in the fieldbus connection between the controller and the device, has no power supply or is faulty dwTcHydErrDistanceInsuffic ient 16#4FF2 20466 The travel path is inadequate.