Knowledge Base The usual asymmetry of the cylinders causes the axis to move too slowly in the slower direction at any commanded velocity when the reference velocity is set. This behavior can be compensated for on the Valve tab by using the velocity ratio parameter. When the behavior is symmetrical, this parameter should be set to 1,000. If the positive direction of travel is the slower direction, use a value greater than 1,000. If the negative direction of travel is the slower direction, a value less than 1,000 should be used. This increases the output in the slower direction and compensates for the asymmetry. NOTE!
With this compensation, the output can only be increased up to its maximum value. The parameterization must be carried out at velocities that the axis can reach in both directions. NOTE! If the parameter is changed in the wrong direction, the velocity decreases in the faster direction. In this case the reference velocity must not be corrected. 5.7.8 Referencing For incremental position measuring systems: Now at the latest, the axis should be referenced correctly and fully. Enter the index velocity, index direction, sync velocity, sync direction and the reference position under the Encoder tab. For more information see MC_Home_BkPlcMc [ } 57] . NOTE!
It may be necessary to reset the travel limits. 5.7.9 Dynamics/target approach At this point in time, the axis is able to position with different velocities and moderate dynamics. On the Monitor tab you can set when the axis should report ready. An axis is in the target if the remaining distance is smaller than PosRange and BrakeDistance; for the TargetFilterTime the remaining distance must be smaller than Targetrange. These three parameters must be set appropriately according to the application requirements. The user subsequently has to decide whether the axis should be positioned time-based or displacement- based. PLC Library Hydraulics 265 Version: 1.4