TwinCAT PLC Library Hydraulics - Version 1.4 — 5.7.9.2 Time-based axis control

Knowledge Base Most hydraulic applications can be operated path-controlled. If, however, time-based profile generation is necessary, the TimeBased check mark should be set. 5.7.9.1 Displacement-based axis The position controller is only active for the target approach. The acceleration can be set so steeply that the axis gently accelerates without significant jerks when it starts moving. For braking on the target approach, not only the deceleration but also the creep distance, creep velocity and braking distance must be set. All three parameters depend on each other and influence the target approach. If the axis is within the braking distance, it is only controlled by the position controller.

The creep velocity and creep distance are used to stabilize the axis after deceleration, in order to take it to its target via the position controller. The target approach should look like this: It is often observed that an axis that is extremely slowed down requires a longer creep phase in order to position as accurately as an axis with a gentler deceleration. 5.7.9.2 Time-based axis control If the axis control is to be time-based, the position controller is active during the entire motion. This option should only be used for axes with a high natural frequency and ideally with a zero overlap valve. The acceleration must be limited to values that the axis can follow without strong vibration.

Special attention should be paid to starting up. When braking, the deceleration must be adjusted so that the axis can follow the set value ramp. The creep velocity, creep distance and braking distance can be set to zero. The actual position must follow the set position to avoid overshooting. If this is not the case, the pre-control must be reduced. At this point, the axis is fully commissioned for positioning. If a pressure regulator, cam plate or gear coupling is used in the application, these elements must also be put into operation. PLC Library Hydraulics 266 Version: 1.4