TwinCAT PLC Library Hydraulics - Version 1.4 — 4.3.9 E_TcMCParameter (from V3.0)

PLCopen Motion Control McPara_BkPlcMc_CustomerData: A field with parameters that can be used freely by an application. These parameter are stored and loaded with the axis parameters. McPara_BkPlcMc_CycleDevider: reserved, not implemented. McPara_BkPlcMc_CylinderArreaA: The cylinder area of the cylinder side pushing in positive direction. McPara_BkPlcMc_CylinderArreaB: The cylinder area of the cylinder side pushing in negative direction. McPara_BkPlcMc_DigInputsReversed: Enable for inversion of the input signals of an axis with digital position sensors. McPara_BkPlcMc_DriveAbsoluteOutput: Enable for absolute value formation during output adjustment. McPara_BkPlcMc_DriveDefaultPowerOk:

Drive power is assumed to be available adopted; no hardware signal required. McPara_BkPlcMc_DriveIncInterpolation: Interpolation of the output adjustment. McPara_BkPlcMc_DriveIncWeighting: Weighting of the output adjustment. McPara_BkPlcMc_DriveReversed: Enable for inverted output adjustment. McPara_BkPlcMc_DriveType: Type of drive adjustment. McPara_BkPlcMc_EmergencyRamp: In the event of an emergency stop: The time for braking from maximum velocity to standstill. McPara_BkPlcMc_EnableControlLoopOnFaults: Enable for position control in the event of axis errors. McPara_BkPlcMc_EncoderBaseDistance: Reserved for distance-coded encoders. McPara_BkPlcMc_EncoderDefaultHomePosition:

Axes with incremental distance measuring system: A default value for homing. McPara_BkPlcMc_EncoderEnableLatch: Enable for the latch function of an encoder hardware. McPara_BkPlcMc_EncoderHomingType: Axes with incremental distance measuring system: The default homing method. McPara_BkPlcMc_EncoderIncInterpolation: The increment interpolation of the encoder evaluation. McPara_BkPlcMc_EncoderIncWeighting: The increment weighting of the encoder evaluation. McPara_BkPlcMc_EncoderModuloBase: reserved, not implemented. McPara_BkPlcMc_EncoderLatchedPosition: The latched position during homing. McPara_BkPlcMc_EncoderOverrunMask: A mask for detecting an encoder overflow.

McPara_BkPlcMc_EncoderPositionMask: A mask for isolating the valid bits within the mapped variables. McPara_BkPlcMc_EncoderPotiRgToRl: For potentiometer encoders: The ratio of total potentiometer resistance to load resistance (input resistance of the terminal). McPara_BkPlcMc_EncoderRefFlag: The homing status of the axis. McPara_BkPlcMc_EncoderRefIndexPositive: Axes with incremental distance measuring system: During homing the system looks for the index (cam) in positive direction. McPara_BkPlcMc_EncoderRefIndexVelo: Axes with incremental distance measuring system: During homing the system looks for the index (cam) with this velocity. McPara_BkPlcMc_EncoderRefShift:

Axes with incremental distance measuring system: Zero shift of the encoder evaluation. McPara_BkPlcMc_EncoderRefSyncPositive: Axes with incremental distance measuring system: During homing the system looks for the homing signal in positive direction. PLC Library Hydraulics 84 Version: 1.4