PLCopen Motion Control McPara_BkPlcMc_EncoderRefSyncVelo: Axes with incremental distance measuring system: During homing the system looks for the homing signal with this velocity. McPara_BkPlcMc_EncoderReversed: Enable for inverted encoder evaluation. McPara_BkPlcMc_EncoderType: Type of encoder evaluation. McPara_BkPlcMc_EncoderZeroShift: Axes with absolute distance measuring system: Zero shift of the encoder evaluation. McPara_BkPlcMc_EncoderZeroSwap: Block-by-block shifting of the counting range of the encoder evaluation. McPara_BkPlcMc_EnvCycleTime: The cycle time of the task in which the core blocks (encoder, setpoint generator, etc.) of the axis are called. McPara_BkPlcMc_FeedForward:
Pre-control weighting of the axis. McPara_BkPlcMc_JerkEnabled: The control word for jerk limitation. McPara_BkPlcMc_JogVeloFast: A default value for a fast jog velocity. McPara_BkPlcMc_JogVeloSlow: A default value for a slow jog velocity. McPara_BkPlcMc_LagAmp: Gain factor for the proportional component in the position controller. McPara_BkPlcMc_LagAmpAdaptFactor: Reserved. McPara_BkPlcMc_LagAmpAdaptLimit: Reserved. McPara_BkPlcMc_LagAmpCfb_tA : Reserved. McPara_BkPlcMc_LagAmpCfb_kA : Reserved. McPara_BkPlcMc_LagAmpCfb_tV : Reserved. McPara_BkPlcMc_LagAmpCfb_kV : Reserved. McPara_BkPlcMc_LagAmpDx: Threshold value for the integrating component of the position controller.
McPara_BkPlcMc_LagAmpTd : Reserved. McPara_BkPlcMc_LagAmpTdd : Reserved. McPara_BkPlcMc_LagAmpTi: Time constant for the integrating component of the position controller. McPara_BkPlcMc_LagAmpOutLimit: Output limitation for the position controller. McPara_BkPlcMc_LagAmpWuLimit: Limitation (wind-up limit) for the integrating component of the position controller. McPara_BkPlcMc_LogLevel: Threshold value for message logging. McPara_BkPlcMc_MonDynamicLagLimit: Tolerance for dynamic position lag monitoring. McPara_BkPlcMc_MonPehEnable: Enable for monitoring of the ready message at the target. McPara_BkPlcMc_MonPehTimeout: Filter time for monitoring of the ready message at the target.
McPara_BkPlcMc_MonPositionLagFilter: Filter time for position lag monitoring. McPara_BkPlcMc_MonPositionRange: Tolerance for the position window. McPara_BkPlcMc_MonTargetFilter: Filter time for the target window. McPara_BkPlcMc_MonTargetRange: Tolerance for the target window. McPara_BkPlcMc_obsolete_XYZ: Placeholder for parameters that are no longer supported. These parameter codes must not be reused for new parameters. To ensure this, such numerical values are assigned names of this form. PLC Library Hydraulics 85 Version: 1.4