Editors The flow control is run with the "Online" "Flow control" command. Using the flow control, you can view the present values that are being carried in the networks over the connecting lines. If the connecting lines do not carry Boolean values, then the value will be displayed in a specially inserted field. The monitor fields for variables that are not used (e.g. in the function SEL) are displayed in a shade of grey. If the lines carry Boolean values, then they will be shaded blue, in the event that they carry TRUE. Therefore, you can accompany the flow of information while the PLC is running.
If you place the mouse pointer briefly above a variable, then the type and the comment about the variable will be displayed in a Tooltip. 5.6 Function Block Diagram Editor This is how a POU written in the FBD under the corresponding TwinCAT PLC Control editor looks: Editor for the Function Block Diagram The Function Block Diagram editor is a graphic editor. It works with a list of networks, in which every network contains a structure that displays, respectively, a logical or an arithmetical expression, the calling up of a function block, a function, a program, a jump, or a return instruction.The most important commands are found in the context menu (right mouse button).
Cursor positions in FBD Every text is a possible cursor position. The selected text is on a blue background and can now be changed. You can also recognize the present cursor position by a dotted rectangle. The following is a list of all possible cursor positions with an example: 1) Every text field (possible cursor positions framed in black): TX1200 132 Version: 1.3