Resources Sampling Trace of Eight Different Variables without a Trigger If a trace buffer is loaded, then the values of all variables to be displayed will be read out and displayed. If no scan frequency has been set, then the X axis will be inscribed with the continuous number of the traced value. The status indicator of the trace window (first line) indicates whether the trace buffer is full and when the trace is completed. If a value for the scan frequency was specified, then the x axis will specify the time of the value. The time is assigned to the "oldest" traced value. In the example, e.g., the values for the last 25 seconds are indicated. The Y axis is inscribed with integer values.
The scaling is laid out in a way that allows the lowest and the highest value to fit in the viewing area. In the example, Var5 has taken on the lowest value of 6, and the highest value of 11: hence the setting of the scale at the left edge. If the trigger requirement is met, then a vertical dotted line is displayed at the interface between the values before and after the appearance of the trigger requirement. A memory that has been read will be preserved until you change the project or leave the system 'Extras' 'Cursor Mode' The easiest way to set a cursor in the monitoring area is to click there with the left mouse button. A cursor appears and can be moved by the mouse.
At the top of the monitoring window the current x-position of the cursor is displayed. In the fields next to 'Var 0', 'Var 1', ..., 'Var n' the value of the respective variable is shown. Another way is the command 'Extras' 'Cursor mode'. With this command two vertical lines will appear in the Sampling Trace. First they are laying one on the other. One of the lines can be moved to the right or to the left by the arrow keys. By pressing + or + the speed of the movement can be increased. If the mouse pointer is located in the graphics window and the left mouse button is pressed, then the cursor will likewise be displayed.
If additionally the key is pressed, the second line can be moved, showing the difference to the first one. 'Extras' 'Multi Channel' With this command you can alternate between single-channel and multi-channel display of the sampling trace. In the event of a multi-channel display, there is a check in front of the menu item. The multi-channel display has been preset. Here the display window is divided into as many as eight display curves. For each curve the maximum and the minimum value are displayed at the edge. In a single-channel display, all curves are displayed with the same scaling factor and are superimposed. This can be useful when displaying curve abnormalities.
'Extras' 'Y Scaling' With this command you can change the preset Y scaling of a curve in the trace display. In the dialog box specify the number of the desired curve ( Channel ) and the new maximum ( maximum y scale ) and the new minimum value ( minimum y scale ) on the y axis. By doubleclicking on a curve you will also be given the dialog box. The channel and the former value are preset. Dialog Box for Setting the Y Scale 'Extras' 'Stretch' With this command you can stretch (zoom) the values of the sampling tracethat are shown. The beginning position is set with the horizontal picture adjustment bar.
With repeated stretches that follow one-after- another, the trace section displayed in the window will increasingly shrink in size. This command is the counterpart to "Extras" "Compress" . TX1200 178 Version: 1.3