Reference programming TX1200 228 Version: 1.3 Number Error Message Possible Cause 1806 ' '(' '): The target setting 'Alarm handling in the PLC' should be set. You are using an element for alarm visualization. This however will not be regarded on the PLC because option 'Alarm handling in the PLC' is not activated in the target settings, category 'Visualization'. 1807 ( ): No message window for alarms for target visualization Regard that action "message" is not supported for the Target- Visualization! 1850 Input variable at %IB is used in task ' ' but updated in another task Please check which tasks are using this variable and whether the current programming is not causing undesirable effects.
The update of the variable value usually is done in the task with the highest priority. 1851 Output variable at %IQ is used in task ' ' but updated in another task Please check which tasks are using this variable and whether the current programming is not causing undesirable effects. The update of the variable value usually is done in the task with the highest priority. 1852 CanOpenMaster might not be called cyclically in event task ' '! Set modul parameter UpdateTask! Currently the CanOpen Master is called by the named event task. If you want to get it called cyclically, specify an appropriate task via parameter UpdateTask in the PLC Configuration in dialog 'Module parameters'.
1853 A PDO (index: ' ') might not be updated cyclically in event task ' ' Currently the named PDO is controlled via the named event task. But if you want to get it called cyclically, you must assign an appropriate task to the PDO by shifting IO-references to this task. POU ' ' (main routine) is not available in the library The Start-POU (z.B. PLC PRG) _ will not be available, when the project is used as library. 1901 Access Variables and Variable Configurations are not saved in a library! Access variables and variable configuration are not stored in the library. 1902 ' ': is no Library for the current machine type! The .obj file of the lib was generated for another device. 1903 :
is no valid Library The file does not have the format requested for the actual target. 1904 The constant ' ' hides a constant of the same name in a library In your project you have defined a constant which has the same name like one which is defined in a linked library. The library variable will be overwritten ! 1970 Parameter manager: List ' ' , Column ' ', Value ' ' could not be imported! Check the Import-file *.prm for entries which do not match the current configuration (standard values resp. XML-description file) of the Parameter Manager.