Reference programming TX1200 233 Version: 1.3 Number Error Message Possible Cause 3403 Could not import The section for object in the .exp file is not correct. 3404 An error occurred during import of task configuration The section for the task configuration the .exp file is not correct. 3405 An error occurred during import of PLC configuration The section for the PLC configuration in the .exp file is not correct. 3406 Two steps with the name ' The section for the SFC POU in the .exp file contains two steps with equal names. Rename one of the steps in the export file. 3407 Predecessor step ' ' not found The step is missing in the .exp file.
3408 Successor step ' ' not found The step is missing in the .exp file. 3409 No successional transition for step ' ' In the .exp file a transition is missing, which requires step as preceeding step. 3410 No successional step for transition ' ' In the .exp file a step is missing which requires the transition as preceeding condition. 3411 Step ' ' not reachable from initial step In the .exp file the connection between step and the initial step is missing. 3412 Macro ' ' not imported Check the export file. 3413 Error during import of the CAMs. You have imported an export file (*.exp) which contains erroneous information on a CAM. Check the export file.
3414 Error during import of the CNC program list You have imported an export file (*.exp) which contains erroneous information on a CNC program. Check the export file. 3415 Error during import of the Alarm configuration You have imported an export file (*.exp) which contains erroneous information on the Alarm Configuration. Check the export file. 3450 PDO' ': Missing COB-Id! Click on the button ‚Properties’ in the PLC configuration dialog for the module and enter a COB ID for the PDO . 3451 Error during load: EDS-File ' ' could not be found, but is referenced in hardware configuration! Eventually the device file needed for the CAN configuration is not in the correct directory.
Check the directory setting for configuration files in ‚Project' 'Options' 'Directories'. 3452 The module ' ' couldn't be created! The device file for module does not fit to the current configuration. Eventually it has been modified since the configuration has been set up or it is corrupted. 3453 The channel ' ' couldn't be created! The device file for channel does not fit to the current configuration. Eventually it has been modified since the configuration has been set up or it is corrupted. 3454 The address ' ' points to an used memory! Option 'Check for overlapping addresses' is activated in the dialog ‚Settings’ of the PLC configuration and an overlap has been detected.
Regard, that the area check is based on the size which results of the data types of the modules, the size which is given by the entry ‚size’ in the configuration file. 3455 Error during load: GSD-File ' ' could not be found, but is referenced in hardware configuration! Eventually the device file required by the Profibus configuration is not in the correct directory. . Check the directory setting for configuration files in ‚Project' 'Options' 'Directories'.