Beckhoff Automation GmbH & Co. KG TX1200 — 7.5 Compiler Errors

Reference programming TX1200 236 Version: 1.3 Number Error Message Possible Cause 3562 Task ' ': external event tasks are not supported by the current target The current task configuration contains external event tasks which are not supported by the currently set target system. Change target or modify the task configuration correspondingly. 3563 The interval of task ' ' is out of valid range between ' ' and ' ' Change the interval value in the configuration dialog for the task. 3564 The external event ' ' of task ' ' is not supported by the current target The currently set target system does not support the external event which is defined in the task configuration for this task.

Change target or modify the task configuration correspondingly. 3565 Maximum number of event tasks (' ') exceeded The currently set target system does not allow as many event tasks as are defined at the moment. Change target or modify the task configuration correspondingly. 3566 Maximum number of interval tasks (' ') exceeded The currently set target system does not allow as many interval tasks as defined at the moment. Change target or modify the configuration correspondingly. 3567 Maximum number of free wheeling tasks (' ') exceeded The currently set target system does not allow as many free wheeling tasks as defined at the moment. Change target or modify the configuration correspondingly.

3568 Maximum number of external interval tasks (' ') exceeded The currently set target system does not allow as many external interval tasks as defined at the moment. Change target or modify the configuration correspondingly. 3569 POU ' ' for system event ' ' not defined The POU which should be called by the named system event, as defined in the task configuration, is not available in the project. Modify the task configuration correspondingly or make sure that the POU is available in the project. 3570 The tasks ' ' and ' ' share the same priority Modify the task configuration so that each task has a different priority. 3571 The library 'SysLibCallback' is not included in the project!

System events can not be generated. In order to create event tasks, the SysLibCallback.lib is needed. Link this library to the project in the library manager or modify the task configuration (task attributes) in that way that there is no task triggered by an event. 3575 Task ': the cycle time has to be a multiple of μs. Correct the cycle time accordingly in the Taskattributes dialog for this task. The target system defines a base time and prescribes that the cycle time must be equal to or be a multiple of this base time. Implicit variables not found! Use command ‚Rebuild all’. If nevertheless you get the error message again please contact the PLC manufacturer.

3601 is a reserved variable name The given variable is declared in the project, although it is reserved for the codegenerator. Rename the variable. 3610 ' ' not supported The given feature is not supported by the current version of the programming system. 3611 The given compile directory ' ' is invalid There is an invalid directory given in the ‚Project’ ‚Options’ ‚Directories’ for the Compile files.