Beckhoff Automation GmbH & Co. KG TX1200 — 7.5 Compiler Errors

Reference programming TX1200 237 Version: 1.3 Number Error Message Possible Cause 3612 Maximum number of POUs ( ) exceeded! Compile is aborted. Too many POUs and data types are used in the project. Modify the maximum number of POUs in the Target Settings / Memory Layout. 3613 Build canceled The compile process was cancelled by the user. 3614 Project must contain a POU named ' ' (main routine) or a task configuration Create an init POU of type Program (e.g. PLC PRG) or set up a task configuration. _ 3615 (main routine) must be of type program A init POU (e.g. PLC PRG) is used in the _ project which is not of type Program.

3616 Programs musn't be implemented in external libraries The project which should be saved as an external library contains a program. This will not be available, when the library will be used. 3617 Out of memory Increase the virtual memory capacity of your computer. 3618 BitAccess not supported in current code generator! The code generator for the currently set target system does not support bit access on variables. 3619 Object file ' ' and library ' ' have different versions! Make sure that for the library there are available matching versions of *.lib and *.obj resp. *.hex files. These files must have the very same time stamp.

3620 The POU ' ' must not be present inside a library You want to save the project as a library of version 2.1. In this version a library may not contain a PLC PRG object. Use a different _ POU name. 3621 "Cannot write compile file ' '" Probably in the path which is specified for the compile file there is already a file of the same name, which is "read only". Remove that file resp. change the access rights. 3622 "The symbol file ' ' could not be created" Probably in the path which is specified for the symbol file (usually project directory) there is already a file of the same name, which is "read only". Remove that file resp. change the access rights.

3623 "Cannot write boot project file ' '" Probably in the path which is specified for the symbol file (target specific) there is already a file of the same name, which is "read only". Remove that file resp. change the access rights. 3624 "Target setting = not compatible with = " Check and correct these settings in the Targetsettings dialogs (Ressources tab). If the settings are not visible resp. editable there, please contact the PLC Manufacturer. POU with name ‘ ' is already in library ' ' A POU name is used in the project, which is already used for a library POU. Rename the POU.

3701 Name used in interface is not identical with POU Name Use command ‘Project’ ‘Rename object’ to rename the POU in the object organizer, or change the name of the POU in the declaration window. There the POU name has to be placed next to one of the keywords PROGRAM, FUNCTION or FUNCTIONBLOCK. 3702 Overflow of identifier list Maximum 100 identifiers can be entered in one variable declaration. 3703 Duplicate definition of identifier ' ' Take care that there is only one identifier with the given name in the declaration part of the POU. 3704 data recursion: -> -> .. -> A FB instance was used, which needs itself.