Beckhoff Automation GmbH & Co. KG TX1200 — 7.5 Compiler Errors

Reference programming TX1200 246 Version: 1.3 Number Error Message Possible Cause 4359 Invalid Qualifier: '%s' In the box on the left hand of the action name enter a qualifier for the IEC action. 4360 Time Constant expected after qualifier '%s' Enter next to the box on the left hand of the action name a time constant behind the qualifier. 4361 '%s' is not the name of an action Enter next to the box on the right hand of the qualifier the name of an action or the name of a variable which is defined in the project. 4362 Nonboolean expression used in action: '%s' Insert a boolean variable or a valid action name. 4363 IEC-Step name already used for variable:

' ' Please rename the step or the variable. 4364 A transition must be a boolean expression The result of the transition expression must be of type BOOL. 4365 Time Constant expected after qualifier ' ' Open dialog ‚step attributes’ for the step ' ' and enter a valid time variable or time constant 4366 The label of the parallel branch is no valid identifier: ' ' Enter a valid identifier next to the triangle which marks the jump label. 4367 The label ' ' is already used There is already a jump label or a step with this name. Please rename correspondingly. 4368 Action ' ' is used in multiple step chains, where one is containing the other!

The action ' ' is used in the POU as well as in one or several actions of the POU. 4369 Exactly one network required for a transition There are used several FBD resp. LD networks for a transition. Please reduce to 1 network. 4370 Additional lines found after correct IL-transition Remove the not needed lines at the end of the transition. 4371 Invalid characters following valid expression: ' Remove the not needed characters at the end of the transition. 4372 Step ' ': Time limit needs type 'TIME' Define the time limits of the step in the step attributes by using a variable of type TIME or by a time definition in correct format (e.g. "t#200ms").

4373 IEC-actions are only allowed with SFC-POUs There is an action assigned to a non-SFC-POU (see in the Object Organizer), which is programmed in SFC and which contains IEC actions. Replace this action by one which contains no IEC actions. 4374 Step expected instead of transition ' ' The SFC POU is corrupt, possibly due to any export-import actions. 4375 Transition expected instead of step ' ' The SFC POU is corrupt, possibly due to any export-import actions. 4376 Step expected after transition ' ' The SFC POU is corrupt, possibly due to any export-import actions. 4377 Transition expected after step ' ' The SFC POU is corrupt, possibly due to any export-import actions.

Unrecognized variable or address The watch variable is not declared within the project. By pressing you get the input assistant which lists the declared variables. 4501 Extra characters following valid watch expression Remove the surplus signs. 4520 Error in Pragma: Flag expected before ' '! The pragma is not correct. Check whether ‘ ' is a valid flag. 4521 Error in Pragma: Unexpected element ' '! Check whether pragma is composed correctly.