Visualization Activate options Column heading resp. Row heading , if the headings should be displayed in the alarm table. Category Columns: Define here, which of the columns (alarm parameters) should be displayed in the alarm table: The parameters are defined -- except for date and time (alarm is coming) and alarm state in the Configuration of the alarm groups: Bitmap, Date, Time, Expression, Value, Message, Priority, Type, Class, State, Target value (for alarm types DEV+ and DEV-), Deadband. Dialog for configuration of an alarm table, category 'Columns' Using the buttons ">", ">>", you can take single resp. all parameters from the left to the right window.
The selection defined in the right window will be displayed in the alarm table. Using the buttons " entries can be removed from the selection. For each column you can open the dialog 'Configure columns' by a double-click on the entry in the right window. In this dialog Column header and Column width can be defined. Category Settings for sorting: TX1200 294 Version: 1.3