TwinCAT NC Master Axes 1. Acceleration phases a(t) > 0 : ◦Acceleration increase: da(t)/dt = +J , ◦[Constant acceleration: a(t) = A+ ], ◦Acceleration decrease: da(t)/dt = -J , 2. [Constant velocity phase |v(t)| = V ], 3. Deceleration phases a(t) : ◦Deceleration increase: da(t)/dt = -J , ◦[Constant deceleration: a(t) = -A- ], ◦Deceleration decrease: da(t)/dt = +J . General notes and special cases The start occurs from the current actual position. A start does not occur, if the length of the positioning path is less than an encoder increment (Warning).
If the set velocity V cannot be reached (the distance is too short or V is too large), the largest achievable velocity (under the symmetric acceleration/deceleration A± = min(A+,A-) ) is determined and activated instead of V without notification. If no dynamic profile can be generated with the specified start data, because the jerk is too large, the jerk is automatically rescaled. An override is available via the PLC that changes the set velocity to a percentage between 0.0 and 100.0 . One can, for example, start the axis with override 0.0 , and then increase the override as required. Procedure 1. Prior to a start request:
the Set PreParation task is awaiting new tasks, and in the Set ExeCution task only position control is operating. 2. Set PreParation task : once the start parameters have been checked, a dynamic profile is generated and stored in a runtime table. The setpoint generation of the Set ExeCution task is than automatically enabled. Set ExeCution task : the setpoint generator calculates the current setpoints based on the runtime table and the expired time since the start and transfers them to the position controller. Setpoints for the setpoint generation are the local setpoints, i.e. the following parameters calculated during every cycle:
◦the position setpoint (for position control), ◦the velocity command value (for velocity pre-control), ◦the acceleration setpoint (for control with special controllers), ◦the set direction (for direction-independent feed monitoring). 3. After the end of path: in the Set ExeCution task, once again only the position controller is executed. Notes on the figures : Scales: velocity [mm/s] / time [s] Colors: Set position: dark blue Actual position: light blue Target velocity: dark green Actual velocity: light green Set acceleration: dark red Actual acceleration: light red Following error: yellow TX1250 10 Version: 1.1