beckhoff TX1250 — 2.1 Axis start

TwinCAT NC Master Axes 2.1 Axis start At the axis start, a jerk-limited dynamic profile is generated via the standard dynamic parameters (acceleration, deceleration, jerk) and the start parameters (set velocity and target position), and stored in form of a table (run time table), which is then used for the generation of the set values within the block execution task. Units and reference systems Basic and pre-set units are millimeter [mm] and second [s], although the position can also be displayed in modulo values. Here, the units used are mm and s . The axis can be started from its current position absolute, relative or modulo (in relation to a given modulo factor) to a target position.

The direction of travel of the axis is determined on the basis of the sign of the modulo position . If a modulo position smaller than the modulo factor is specified, (default value 360.0) the shortest path to that modulo position will be taken, with the specified direction being maintained. This end position may still be in the same or in the next modulo period (depending on the start position). In case of modulo position 0.0 , the sign cannot be used to determine the direction of travel. By definition, this case is interpreted as positive direction of travel. To approach the position 0.0 in negative direction, a negative value close to 0, e.g. -1e-6 can be specified.

If a modulo position is specified as being greater than or equal to the modulo factor, the target position is no longer reached by the shortest route, but only after the modulo position has been passed over once or several times. As always, the sign defines the direction of travel and the position value divided by the modulo factor defines the number of additional revolutions until subsequently stopping at the corresponding orientation. An example: modulo start at position +540.0 degrees with modulo factor 360.0 means that the axis is moved at least one period (360.0 + 180.0 = 540.0) in positive direction and then is stopped on the shortest way oriented at the modulo position 180.0 degrees.

Here, only absolute positioning is considered. In the following a(t) is used for acceleration, v(t) for velocity and p(t) for position at time t after start of axis. In this context accelerations/decelerations and velocities almost refer to path accelerations/decelerations (path acceleration/deceleration = signum(axis target velocity) Ч axis acceleration/deceleration ) and path velocities ( path velocity = magnitude of axis velocity). Global dynamic parameters Acceleration A+ > 0 : the parameter A+ limits the acceleration upwards, i.e. for the entire positioning applies: a(t) ≤ A+ . Deceleration A- > 0 : the parameter A- limits the acceleration downwards, i.e.

for the entire positioning applies: -A- ≤ a(t) . Jerk unit (change in acceleration) J : the jerk unit controls the increase and reduction in acceleration/ deceleration. If a(t) is not constant, |da(t)/dt| = J , i.e. the change in acceleration will always occur with the maximum permissible value. Acceleration limits A+, A- . Whether the acceleration/deceleration limit(s) ( A+,A- ) are reached depends on the relationship between acceleration limit/deceleration limit and target velocity V .

The value of the jerk J at which the acceleration/deceleration limit is just reached (but not maintained) is the critical jerk J± , which is defined by the equation J+ = (A+)І/V , or J- = (A-)І/V in units mm and s. Start parameters Set velocity V > 0 : the parameter V defines the upper velocity limit, i.e. the following applies for the complete positioning: |v(t)| ≤ V . Target position. The length the positioning path indirectly results from the start position (actual position) and the target position. Velocity profile and acceleration profile The standard dynamics for servo axes is a jerk-limited 7-phase dynamics. The 7 phases are (optional phases are shown in brackets []) TX1250 9 Version:

1.1