TwinCAT Slave Axes Coupling Coupling can only occur when both axes are stationary. Coupling is therefore only a logical allocation and has (as long as the master is not moved) no dynamic consequences, but locks certain functionalities for the slave axis (e.g. start and stop). The coupling flag is set. Coupling interfaces System Manager: Coupling PLC Blocks: Coupling Linear path control The slave follows the movement of the master according to the master positions, the coupling offset and the coupling factor. Master start from 0.0 mm to 20,000.0 mm with V = 2000.0 mm/s at start override 30% and coupling factor 0.75. Then (master) override to 100%, then (master) stop.
Coupling factor The coupling factor (gearing factor) must not equal zero, but may be negative. The following applies: Slave set position = coupling factor * master set position + offset, whereby the offset is determined from the coupling positions, Slave target velocity = coupling factor * master target velocity. TX1250 30 Version: 1.1