TwinCAT Slave Axes Coupling with fixed negative coupling factor: Master start from 0.0 mm to 2000.0 mm with V = 2000.0 mm/s, coupling factor -0.5. Coupling with variable coupling factor: Master start from 0.0 mm to 2000.0 mm with V = 2000.0 mm/s, coupling factor -0.7, new coupling factor -0.8. Changing the coupling factor The coupling factor (not equal zero) may be changed online, but the effects (following error) are in the hands of the user. During travel, the coupling factor should only be changed moderately, since a following error is generated. Changing the coupling factor from plus to minus (of vice versa) causes a motion reversal of the slave axis. TX1250 31 Version: 1.1