TwinCAT Slave Axes tance will generally be equal the required one (or the one calculated at the start). This means that for stop or override 0.0 , the actual compensated distance (absolute) will be less than the required one (or the one calculated at the start). 4. The values AK+ and AK- are increases in path acceleration/path deceleration values, i.e. if D > 0.0, compensation starts with the acceleration increase AK+ , whilst, if D the deceleration increase AK-. Special notes for compensation within slave cascade .
During simultaneous compensation of all axes, let A_m+ be the acceleration of the cascade master axis, AK_m+ the compensation acceleration of the master axis, and AK_sk+ the compensation acceleration of the k-th slave axis, 1 ≤ k ≤ n . Then the following applies ( Π is the product of all k ) A_m+ Ч AK_m+ Π AK_sk+ ≤ A_max+ where A_max+ is the acceleration of the master axis that would be movable without slaves. (If an axis does not take part in the compensation, AK_sk+= 1 is to be used for its acceleration in this equation). Analogous considerations apply for A- .
Compensation stop The function stop terminates the compensation of an axis, if the axis is in compensation mode, but not in the braking phase of compensation, by suitably moving the (temporal) phase limits of the 3-phase algorithm, recalibrating the length of the compensation length L, recalibrating the differential speed and replacing the compensating distance D at the end the compensation by the actual compensated distance. Interfaces Compensation start System Manager: compensation parameters System Manager: start compensation PLC function blocks:
compensation start Compensation stop System Manager PLC function blocks 3.3 Cyclic Slave Axes A slave axis, whose position setpoints are determined from 1. the position setpoints of another axis (master axis) through an affine transformation and 2. a coupling factor set through the cyclic PLC-NC interface within the PLC cycle, is called cyclic slave axis . If the coupling factor changes constantly, e.g. because it depends on an external signal, then the slave algorithm is linear in each PLC cycle, i.e. locally linear and globally non-linear. The following applies:
slave set position = coupling factor(PLC) * master set position + offset, where the offset results from the coupling position and the coupling factor is set again and again. While the coupling of the slave to the master is done offline (master and slave are stationary), the decoupling can be done online: the slave is thereby converted into a master, which continues to move as if it were still a slave, but which can also be stopped independently of the former master. Each online change of the coupling factor causes a discontinuity in the velocity and thus a load on the dynamics of the axis.
In order to avoid excessive strain, the coupling factor arriving via the cyclic interface is therefore smoothed (= filtered). Smoothing is parameterized by limiting the amount of the slave axis acceleration. TX1250 38 Version: 1.1