PMAC Product Guide Ix07 Motor x Master (Handwheel) Scale Factor Range: 8,388,608 .. 8,388,607 Default: 96 Units: none This parameter controls with what scaling the master (handwheel) encoder gets extended into the full- length register. In combination with Ix08, it also controls the following ratio of motor x (delta-motor-x = [Ix07/Ix08] * delta-handwheel-x) for position following (electronic gearing). For following, Ix07 and Ix08 can be thought of as the number of teeth on meshing gears in a mechanical coupling. Ix07 can be changed on the fly to permit real-time changing of the following ratio, but Ix08 may not. Ix08 Motor x Position Scale Factor Range: 0 .. 8,388,607 Default: 96 Units:

none This parameter controls how the position encoder counter gets extended into the full-length register. For most purposes, this is transparent and does not need to be changed from the default. There are two reasons to change this from the default value. First, because it is involved in the gear ratio of the position following function -- the ratio is Ix07/Ix08 -- this might be changed (usually raised) to get a more precise ratio. The second reason to change this parameter (usually lowering it) is to prevent internal saturation at very high gains or count rates (velocity). PMAC’s filter will saturate when the velocity in counts/sec multiplied by Ix08 exceeds 768M (805,306,368).

This only happens in rare applications -- the count rate must exceed 8.3 million counts per second before the default value of Ix08 gives a problem. When changing this parameter, make sure the motor is killed (disabled). Otherwise, a sudden jump will occur, because the internal position registers will have changed. This means that this parameter should not be changed in the middle of an application. If a real-time change in the position-following gear ratio is desired, Ix07 should be changed. In most practical cases, Ix08 should not be set above 1000 because higher values can make the servo filter saturate too easily.

If Ix08 is changed, Ix30 should be changed inversely to keep the same servo performance (e.g. if Ix08 is doubled, Ix30 should be halved). Ix09 Motor x Velocity Loop Scale Factor Range: 0 .. 8,388,607 Default: 96 Units: none This parameter controls how the encoder counter used to close the velocity servo loop gets extended into the full-length register. For most purposes, this is transparent and does not need to be changed from the default. This parameter should not be changed in the middle of an application, because it scales many internal values. If the same sensor is used to close both the position and velocity loops (Ix03=Ix04), Ix09 should be set equal to Ix08.

If different sensors are used, Ix09 should be set such that the ratio of Ix09 to Ix08 is inversely proportional to the ratio of the velocity sensor resolution (at the load) to the position sensor resolution. I-Variables 107