omron — Ix25 Motor x Limit/Home Flag/Amp Flag Address

PMAC Product Guide The overtravel-limit inputs specified by this parameter must be held low in order for motor x to be able to command movement. The polarity of the amplifier-fault input is determined by a high-order bit of this parameter (see below). The polarity of the home-flag input is determined by Encoder/Flag I-Variables 2 and 3 for the specified encoder. The polarity of the amplifier-enable output is determined by Jumper E17. Extended Addressing: The source address of the flag information occupies bits 0 to 15 of Ix25 (range $0000 to $FFFF, or 0 to 65535).

If this is all that is specified -- that is, all higher bits are zero -- then all of the flags are used, and used in the normal mode (low-true FAULT, disabling all motors). If higher bits are set to one, some of the flags are not used, or used in an alternate manner, as documented below. In the extended versions, it is easier to specify this parameter in hexadecimal form. With I9 at 2 or 3, the value of this variable will be reported back to the host in hexadecimal form. Ix25 - Motor x Flag Address and Modes Modes PMAC address of flags Hex($) Bin Amplifier Enable Use Bit: With bit 16 equal to zero -- the normal case -- the AENAn/DIRn output is used as an amplifier-enable line:

off when the motor is killed, on when it is enabled. Voltage polarity is determined by jumper(s) E17. If bit 16 (value $10000, or 65536) is set to one (e.g. I125=$1C000), this output is not used as an amplifier-enable line. This permits use of the line as a direction bit for applications requiring magnitude- and direction outputs, such as driving steppers through voltage-to-frequency converters. (Setting bit 16 of Ix02 to 1 enables use of this output as a direction bit.) General-purpose use of this output is also possible by assigning an M-Variable to it. Overtravel Limit Use Bit:

With bit 17 equal to zero -- the normal case -- the +/-LIMn inputs must be held low to permit commanded motion in the appropriate direction. If there are not actual (normally closed or normally conducting) limit switches, the inputs must be hardwired to ground. 114 I-Variables 5 2 C 0 0 4 0 1 0 1 0 0 1 0 1 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 =0 Use amplifier enable function =1 Do not use amplifier enable function =0 Enable position limits =1 Disable position limits =0 Enable amplifier fault input =1 Disable amplifier fault input =00 Kill all PMAC motors on fault or F.E. =01 Kill all C.S. motors on fault or F.E. =1x Kill this motor only on fault or F.E.

=0 Low true fault input =1 High true fault input