PMAC Product Guide Warning: Do not set both Ix20 and Ix21 to 0 simultaneously, even relying on Ix19 to limit the acceleration or a division-by-zero error will occur in the jog move calculations, possibly resulting in erratic motion. A change in this parameter will not take effect until the next move command. For instance, if a different deceleration time is needed from the acceleration time in a jog move, specify the acceleration time, command the jog, change the deceleration time, then command the jog move again (e.g. J= ), or at least the end of the jog ( J/ ). Ix22 Motor x Jog Speed Range: Positive floating point Default: 32.0 Units:
Counts / msec This parameter establishes the commanded speed of a jog move or a programmed RAPID -mode move (if I50=0) for motor x. Direction of the jog move is controlled by the jog command. A change in this parameter will not take effect until the next move command. For instance, if you wanted to change the jog speed on the fly, start the jog move, change this parameter, then issue a new jog command. Ix23 Motor x Homing Speed and Direction Range: Floating point Default: 32.0 Units: Counts / msec This parameter establishes the commanded speed and direction of a homing-search move for motor x.
Changing the sign reverses the direction of the homing move -- a negative value specifies a home search in the negative direction; a positive value specifies the positive direction. Ix25 Motor x Limit/Home Flag/Amp Flag Address Range: Extended legal PMAC X addresses Default: Units: Extended legal PMAC X addresses This parameter tells PMAC what set of flags it will look to for motor x’s overtravel limit switches, home flag, amplifier-fault flag, amplifier-enable output, and index channel. Typically, these are the flags associated with an encoder input; specifically, those of the position feedback encoder for the motor.
If dual-loop feedback is used (Ix03 and Ix04 are different) Ix25 should be set to match the position-loop encoder, not the velocity-loop. Note: To use PMAC’s Hardware Position Capture for homing search moves, the channel number of the flags specified by Ix25 must match the channel number of the encoder specified by Ix03 for position-loop feedback. I-Variables 113 Variable Hex Decimal Limit and Flag Set I125 $C000 (49152) (LIM1, HMFL1…) I225 $C004 (49156) (LIM2, HMFL2…) I325 $C008 (49160) (LIM3, HMFL3…) I425 $C00C (49164) (LIM4, HMFL4…)